TrustSeal Verified

New Items

RDSO Approved Earthing with RITES & Consignee Inspection

Rs 7,500 / Piece

RDSO Approved Earthing with RITES & Consignee Inspection
  • Length Of Rod: As per requirement
  • Equipment Type: Copper Bonded Grounding Rod
  • Rod Diameter: As per requirement
  • Usage/Application: Railway Project
  • Material: Copper
  • Length Of Rod: As per requirement
  • Equipment Type: Copper Bonded Grounding Rod
  • Rod Diameter: As per requirement
  • Usage/Application: Railway Project
  • Material: Copper
  • Diameter: As per requirement
Specifications:
  • RDSO SPN 197
  • RDSO SPN 176
  • RDSO PE SPEC PS 0109
know more

RDSO/PE/SPEC/PS/0109-2008 Earth Electrode

Rs 7,000 / Piece

RDSO/PE/SPEC/PS/0109-2008 Earth Electrode
  • Length Of Rod: As per requirement
  • Equipment Type: UL Listed
  • Finish: Polished
  • Usage/Application: Railway Project
  • Material: Copper
  • Diameter: As per requirement
  • Length Of Rod: As per requirement
  • Equipment Type: UL Listed
  • Finish: Polished
  • Usage/Application: Railway Project
  • Material: Copper
  • Diameter: As per requirement
  • I Deal In: New Only
  • Country of Origin: Made in India
RDSO/PE/SPEC/PS/0109-2008 having diameter not less than 17 mm complying with requirements of BS 4360 Grade 43A or EN10025:2-004 S275JR, molecularly bonded by 99.99% pure high conductivity copper on outer surface with copper coating thickness 250 micron or more, Length 3000 mm (minimum). Length of the electrode may be increased in multiple of 1 meter to reduce earth resistance if required. To increase the length, pieces of similar rod shall be either exothermally welded to basic 3 meter electrode or connected using socket of suitable size. These sockets shall also be molecularly bonded by 99.99% pure high conductivity copper on inner & outer surface with copper coating thickness 250 micron or more. Copper bus bar of size 250 mm x 50 mm x 6 mm having electrical conductivity of 101% IACS, minimum 99.9% copper content shall be exothermically welded to rod with 4 holes of 12 mm dia. (2 on each side) for connecting earthing conductor. Current carrying capacity: The design of the electrode should be such as to have more than 15kA current carrying capacity for 1 second.


Concentric pipe earth electrode:

  • Primary conductor: MS pipe with 25 - 50 mm diameter, class B, ISI mark as per IS-1239, Length 2000 or 3000 mm
  • Secondary conductor: MS pipe with 40-100 mm diameter, class B, ISI mark as per IS-1239, Length 2000 or 3000 mm
know more